Adela Series Steam Sterilizers
ADELA Series Steam Sterilizers
 

ADELA-OT series steam sterilizers are designed and manufactured regarding the manufacturing and product standards.

General Characteristics

 

Control System:

PLC CPU, Dual CPU (Optional)

Operation Mod:

Fully Automatic / Button Command

Screen Type:

Multi-Color TFT, LCD Touch Screen

Screen Size:

7,0" (10,0" Optional)

Keypad:

Touch Screen

Printer:

40 Character /Line, Thermal Printer

Remote Control and Communication:

RS 232 Port / USB , Ethernet (Optional)

Warning Sytem:

Visual & Audio & Printed

Data Storage:

Up to 200 Cycles, 1000 Cycles (Opitonal)

Monitoring

Touch Screen, Anaolgue Gauges for Chamber, Jacket, Generator and Air Pressure (Manometer)

Mobility

4 Easy positioning on 4 swivel castors and firm fixing on legs

Steam Generator

with pneumatic valves

 

Standard Programs

 

Medical And Surgical Instruments 134°C ~ 60 min
Textile Materials 134°C ~ 60 min
Rubber Articles 121°C ~ 80 min
Liquids in Glass Container 121°C ~ 60 min
Liquids in Glass Container 125°C ~ 60 min
Flash 134°C ~ 20 min
Prion 134°C ~ 90 min
Bowie & Dick Test 134°C ~ 45 min
Vacuum Leak Test   ~ 25 min
Customizable Program Capacity   99

 

 
 
 
 
 
Safety and Quality

 

Protects operator from electrical current leaks.

Short circuit protection.

Safety valve.

Hepa filter for air filtration.

Water level control via buoy in generator.

Pneumatic Valves for precise exhausting.

Leak test.

Pre-vacuum cycle

Password protection.

Sensors against obstructions on the doors pathway.

Doors locks under pressure.

Emergency stop button.

Unable to open both doors at once double door models.

 

Relevant Directives and Standards

 

Medical Device Directive

MDD 93/42/EEC / 2007/47/EC

Medical Device Class

Class IIb, MDD 93/42/EEC, 2007/47/ EC (Annex IX)

Low Voltage Directive

2014/35/EU - EN 61010-2-040 - EN 61010-1 - EN 60601-1

EMC Directive

2014/30/EU EN 60601-1-2 - EN 61326-1

Pressure Equipments Directive

PED 2014/68/EU : EN 13445-1, -2, -3, -4, -5

Steam Sterilizer Directive

EN285

Quality Mangement System

ISO 9001

Medical Devices Quality Mangement System

ISO 13485

Enviromental Management Systems

ISO 14001

 

®"Type tests" of Sümer A.S. Steam sterilizers are performed and certified according to the directives of EN 285 and TS EN 17665-1-2 by The German accreditation company HYGCEN GmbH.

 

 

 

Technical Data
 
 
 
CHAMBER VOLUME (LITER) AND DIMENSIONS
MODELS Single door Double door
100L 150L 250L 325L 425L 580L 150L 250L 325L 425L 580L 718L 900L
Height (mm) 390 390 500 500 670 670 390 500 500 670 670 670 670
Width (mm) 390 390 500 500 670 670 390 500 500 670 670 670 670
Depth (mm) 700 1000 1000 1300 1000 1300 1000 1000 1300 1000 1300 1600 2000
STU
Capacity
1 1.5 1.5 2 6 8 1.5 1.5 2 6 8 10 12
DEVICE DIMENSION
MODELS Single door Double door
100L 150L 250L 325L 425L 580L 150L 250L 325L 425L 580L 718L 900L
Height (mm) 1655 1655 1765 1765 1935 1935 1655 1765 1765 1935 1935 1935 1935
Width (mm) 885 885 995 995 1165 1165 885 995 995 1165 1165 1165 1165
Depth (mm) 1125 1325 1325 1625 1325 1625 1325 1325 1625 1325 1625 1925 2325

INSTALLATION CONDITION: At least 60 cm. space is needed on both lateral sides of the device to provide an effective technical service. Exhaust fan or ventilation funnel needs to be placed above the device for an effective evacuation of heat.

*ALL specifications herein are provided for information purposes only and may be modified without notice.

DRAINAGE
Water Inclined pipe to be installed onsite with at least 2 m of length (Diamond.2"-3")
Steam Pneumatic valve, software controlller
Air Vacuum Motor (Built-in)
TEMPERATURE
Range 115*C - 137*C (Chamber)
Measurement PT 100 (DIN A Class)
Sensor Position Chamber (1)
PRESSURE
Measurement Pressure Sensor (4)
Sensor Position Chamber (1), Jacket(1)
Generator (1),Gasket(1)
VACUUM
Source Pump, Doble/Single Water Ring
Pre- Vacuum Yes
DEVICE CONSTRUCTION
Body AISI 304 Stainless Steel
Optional AISI 316 L Stainess Steel
Chamber 6mm, AISI 316 L Stainess Steel
Optional up to 12mm thicked
Jacket 3mm, AISI 316 L Stainess Steel
Optional up to 5mm thicked
Door 10mm, AISI 304 L Stainess Steel
Optional AISI 316 L Stainless Steel
Panel Cover 1-1,5 mm AISI 304 L Stainess Steel
Optional AISI 316 L Stainless Steel
Up to 3mm thickness
Pipes Brass, AISI 304 Stainless Steel,
AISI 316 L Stainless Steel
(Optional)
Chamber
Polishing
Electropolishing,
Sandblasting(Optional)
 

 

 

JACKET
Test Pressure 3.75 Bar
Test Temperature 140 C
Working Temperature 134 C
Working Pressure 2,5 Bar
GENERATOR
Test Pressure 5.25 Bar
Working Temperature 144 C
Working Pressure 3,5 Bar
Water Level Protection *CRES / AISI 304 SS

* CRES: Anti Corrosive Stainless Steel

 

 

ENERGY CONSUMPTION
Electric 20 kW/Loop
Water ~120 Lt/Loop

 

 